Machining center common problem repair

2022-04-23 16:30

Common problem maintenance of vertical machining center


First, the tool library problem disk can not be rotated;


The reason:


1, the tool change process suddenly stopped, can not continue to change the tool;


2, the bamboo hat knife library can not come out;


3, do not loosen the knife during the tool change process;


4. Knife


5, the cutter head suddenly reverse rotation time difference of half a cutter position;


6, when changing the knife, there is a loose knife, tight knife error alarm;


7, in the process of changing the knife, the spindle side sound is very loud;


8, after the replacement, the spindle can not install the knife (loose knife abnormal);


Vertical machining center manufacturers


Countermeasure:


1, whether the air pressure is enough (6 kg);


2, check whether the knife store backward signal is in place, the knife store in and out of the solenoid valve line and PLC output;


3, the amount of punching adjustment, punching cylinder body whether water;


4. When the cutter head comes out and rotates, the cutter motor power cord is open, and the contactor and relay are damaged.


5, the cutter motor brake mechanism is loose and can not brake normally;


6, check the air pressure, whether the cylinder is fully operated (whether there is water), whether the switch is pressed into place, but not too much pressure (with just the signal input principle);


7, adjust the cutting amount;


8, modify the tool change program (macro program O9999);


Second, the machine can not return to zero


The reason:


1, the origin switch contact is stuck and can not operate;


2, the origin block can not press the origin switch to the switch action position;


3, the origin switch water causes the switch contact rusty contact is not good;


4, the origin switch line is disconnected or the input signal source is faulty;


5. PLC input point is burned out.


7. Replace the control circuit board;


8. In case of emergency, the machine can work temporarily after M64S is forced to be ×1A and E60 to be ×32 in I/F diagnosis;


Seven, the program can not be transmitted, P460, P461, P462 alarm


Countermeasure:


1, check whether the transmission line is open, virtual welding, plug is inserted;


2, the computer transmission software side parameters should be consistent with the machine side;


3, replace the computer test transmission;


4, whether the grounding is stable;


8. The machine tool cannot be powered on


The reason:


1, the power switch three-phase contact is bad or the switch is damaged;


2. The operation panel cannot be powered on.


Telephone consultation:15040526358
Online message
Wechat customer service
Scan code consulting